Part Number Hot Search : 
10N65 VNN3NV04 F1003 IT8710F 5M0280 5M0280 AT1382B MPD300
Product Description
Full Text Search
 

To Download RHR1K160D Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 RHR1K160D
Data Sheet January 2000 File Number 4788
1A, 600V Hyperfast Dual Diode Features [ /Title The RHR1K160D is a hyperfast dual diode with soft recovery * Hyperfast with Soft Recovery . . . . . . . . . . . . . . . . . . <25ns (RHR1 characteristics (t rr < 25ns). It has about half the recovery * Operating Temperature. . . . . . . . . . . . . . . . . . . . . . .150oC K160D time of ultrafast diodes and is silicon nitride passivated ion* Reverse Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . .600V implanted epitaxial planar construction. ) /Sub* Thermal Impedance SPICE(R) Model This device is intended for use as freewheeling/clamping ject diodes and rectifiers in a variety of switching power supplies * Thermal Impedance SABER(c) Model and other power switching applications. Its low stored charge (1A, * Avalanche Energy Rated and hyperfast soft recovery minimize ringing and electrical 600V * Planar Construction Hyper- noise in many power switching circuits reducing power loss in the switching transistors. * Related Literature fast Formerly developmental type TA49185. - TB334, "Guidelines for Soldering Surface Mount Dual Components to PC Boards" Diode) Ordering Information /Autho Applications PART NUMBER PACKAGE BRAND r () * Switching Power Supplies RHR1K160D MS-012AA RHR1K160D /Key* Power Switching Circuits NOTE: When ordering, use the entire part number. For ordering in words tape and reel, add the suffix 96 to the part number, i.e., (Inter- RHR1K160D96. * General Purpose sil Symbol Corpo- Packaging ration, JEDEC MS-012AA NC (1) CATHODE 1 (8) semiBRANDING DASH conANODE 1 (2) CATHODE 1 (7) ductor, 5 Ava1 ANODE 2 (3) CATHODE 2 (6) 2 lanche 3 4 Energy NC (4) CATHODE 2 (5) Rated, Switch ing Absolute Maximum Ratings (Per Leg) TA = 25oC, Unless Otherwise Specified Power RHR1K160D UNITS SupPeak Repetitive Reverse Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VRRM 600 V plies, Working Peak Reverse Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .VRWM 600 V 600 V Power DC Blocking Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VR Average Rectified Forward Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IF(AV) 1 A Switch TA = 65oC ing Repetitive Peak Surge Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IFRM 2 A CirSquare Wave, 20kHz Nonrepetitive Peak Surge Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IFSM 10 A cuits, Halfwave, 1 phase, 60Hz RectifiMaximum Power Dissipation (Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PD 2.5 W ers, Avalanche Energy (See Figures 11 and 12) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E 5 mJ
AVL
Operating and Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TSTG,TJ Maximum Temperature for Soldering Leads at 0.063in (1.6mm) from Case for 10s. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TL Package Body for 10s, See Techbrief 334 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Tpkg
-55 to 150 300 260
oC oC oC
1
1-888-INTERSIL or 321-724-7143 | Copyright (c) Intersil Corporation 2000 SABER is a Copyright of Analogy, Inc.
RHR1K160D
Electrical Specifications
SYMBOL VF IF = 1A IF = 1A, TA = 150oC IR VR = 600V VR = 600V, TA = 150oC trr ta tb QRR CJ RJA IF = 1A, dIF/dt = 200A/s IF = 1A, dIF/dt = 200A/s IF = 1A, dIF/dt = 200A/s IF = 1A, dIF/dt = 200A/s VR = 10V, IF = 0A Pad Area = 0.483 in2 (Note 1) Pad Area = 0.027 in2 (Note 2) (Figure 13) Pad Area = 0.006 in2 (Note 2) (Figure 13) DEFINITIONS VF = Instantaneous forward voltage (pw = 300s, D = 2%). IR = Instantaneous reverse current. trr = Reverse recovery time (See Figure 10), summation of ta + tb . ta = Time to reach peak reverse current (See Figure 10). tb = Time from peak IRM to projected zero crossing of IRM based on a straight line from peak IRM through 25% of IRM (See Figure 10). Qrr = Reverse recovery charge. CJ = Junction Capacitance. RJA = Thermal resistance junction to ambient. pw = Pulse width. D = Duty cycle. NOTES: 1. Measured using FR-4 copper board at 0.8 seconds. 2. 2. Measured using FR-4 copper board at 1000 seconds. (Per Leg) TA = 25oC, Unless Otherwise Specified TEST CONDITION MIN TYP 10.5 5 20 10 MAX 2.1 1.7 100 500 25 50 201 239 UNITS V V A A ns ns ns nC pf
oC/W oC/W oC/W
Typical Performance Curve
10 IF, FORWARD CURRENT (A) IR, REVERSE CURRENT ( A) 10 150oC 1 100oC 0.1
100oC 150oC 1 25oC
0.01
25oC
0.1
0.001 0 0.5 1 1.5 2 2.5 3 3.5 4 0 100 200 300 400 500 600 VF, FORWARD VOLTAGE (V) VR , REVERSE VOLTAGE (V)
FIGURE 1. FORWARD CURRENT vs FORWARD VOLTAGE
FIGURE 2. REVERSE CURRENT vs REVERSE VOLTAGE
2
RHR1K160D Typical Performance Curve
20 TA = 25oC, dIF/dt = 200A/s t, RECOVERY TIMES (ns) 16 t, RECOVERY TIMES (ns)
(Continued)
35 30
TA = 100oC, dIF/dt = 200A/s
trr
25 20 15 10 5
trr
12
tb
ta
8
tb
4
ta
0 0.1
0.5 IF, FORWARD CURRENT (A)
1
0 0.1
0.5 IF, FORWARD CURRENT (A)
1
FIGURE 3. trr, ta AND tb CURVES vs FORWARD CURRENT
FIGURE 4. trr, ta AND tb CURVES vs FORWARD CURRENT
IF(AV), AVERAGE FORWARD CURRENT (A)
50 TA = 150oC, dIF/dt = 200A/s t, RECOVERY TIMES (ns) 40
1.0 DC 0.8 SQ. WAVE 0.6 RJA = 50oC/W
trr
30
tb
20
0.4
10
ta
0.2
0 0.1
0.5 IF, FORWARD CURRENT (A)
1
0 25
50
75
100
125
150
TA, AMBIENT TEMPERATURE (oC)
FIGURE 5. trr, ta AND tb CURVES vs FORWARD CURRENT
FIGURE 6. CURRENT DERATING CURVE
50 CJ , JUNCTION CAPACITANCE (pF)
40
30
20
10
0
0
20
40
60
80
100
VR , REVERSE VOLTAGE (V)
FIGURE 7. JUNCTION CAPACITANCE vs REVERSE VOLTAGE
3
RHR1K160D Typical Performance Curve
10
(Continued)
THERMAL IMPEDANCE
ZJA, NORMALIZED
1
DUTY CYCLE - DESCENDING ORDER 0.5 0.2 0.1 0.05 0.02 0.01
RJA = 50oC/W
PDM 0.1
t1 t2 NOTES: DUTY FACTOR: D = t1/t2 PEAK TJ = PDM x ZJA x RJA + TA 10-3 10-1 100 10-2 t, RECTANGULAR PULSE DURATION (s) 101 102 103
SINGLE PULSE 0.01 10-5 10-4
FIGURE 8. NORMALIZED MAXIMUM TRANSIENT THERMAL IMPEDANCE
Test Circuits and Waveforms
VGE AMPLITUDE AND RG CONTROL dIF/dt t1 AND t2 CONTROL IF L
DUT RG
CURRENT SENSE + VDD IF 0
dIF dt ta
trr
tb
IGBT VGE t1 t2
-
0.25 IRM IRM
FIGURE 9. trr TEST CIRCUIT
L = 20mH R < 0.1 EAVL = 1/2LI2 [VR(AVL) /(VR(AVL) - VDD)] Q1 = IGBT (BVCES > DUT VR(AVL))
FIGURE 10. trr WAVEFORMS AND DEFINITIONS
L CURRENT SENSE Q1
R VAVL + VDD IL IL
DUT VDD -
IV
t0
t1
t2
t
FIGURE 11. AVALANCHE ENERGY TEST CIRCUIT
FIGURE 12. AVALANCHE CURRENT AND VOLTAGE WAVEFORMS
4
RHR1K160D Thermal Resistance vs Mounting Pad Area
JUNCTION TO AMBIENT (oC/W) RJA, THERMAL IMPEDANCE 350 RJA = 110.2 - 25.24 x ln (AREA) 300 250 200 150 100 R = 43.81 - 22.66 x ln (AREA) 50 0.001 0.01 AREA, TOP COPPER AREA (in2) 0.1 239oC/W - 0.006in2 201oC/W - 0.027in2
The maximum rated junction temperature, TJM, and the thermal resistance of the heat dissipating path determines the maximum allowable device power dissipation, PDM, in an application. Therefore the application's ambient temperature, TA (oC), and thermal resistance RJA (oC/W) must be reviewed to ensure that TJM is never exceeded. Equation 1 mathematically represents the relationship and serves as the basis for establishing the rating of the part.
( T JM - T A ) P DM = ---------------------------Z JA (EQ. 1)
In using surface mount devices such as the SOP-8 package, the environment in which it is applied will have a significant influence on the part's current and maximum power dissipation ratings. Precise determination of PDM is complex and influenced by many factors: 1. Mounting pad area onto which the device is attached and whether there is copper on one side or both sides of the board. 2. The number of copper layers and the thickness of the board. 3. The use of external heat sinks. 4. The use of thermal vias. 5. Air flow and board orientation. 6. For non steady state applications, the pulse width, the duty cycle and the transient thermal response of the part, the board and the environment they are in. Intersil provides thermal information to assist the designer's preliminary application evaluation. Figure 13 defines the RJA for the device as a function of the top copper (component side) area. This is for a horizontally positioned FR-4 board with 2 oz. copper after 1000 seconds of steady state power with no air flow. This graph provides the necessary information for calculation of the steady state junction temperature or power dissipation. Pulse applications can be evaluated using the Intersil device SPICE thermal model or manually utilizing the normalized maximum transient thermal impedance curve.
FIGURE 13. THERMAL RESISTANCE vs MOUNTING PAD AREA
Displayed on the curve are RJA values listed in the Electrical Specifications table. These points were chosen to depict the compromise between the copper board area, the thermal resistance and ultimately the power dissipation, PDM . Thermal resistances corresponding to other component side copper areas can be obtained from Figure 13 or by calculation using Equation 2. The area, in square inches is the top copper board area, the thermal resistance and ultimately the power dissipation, PDM .
R JA = 110.18 - 25.24 x ln ( Area ) (EQ. 2)
While Equation 2 describes the thermal resistance of a single die, the dual die SOP-8 package introduces an additional thermal component, thermal coupling resistance, R. Equation 3 describes R as a function of the top copper mounting pad area.
R = 43.81 - 22.66 x ln ( Area ) (EQ. 3)
The thermal coupling resistance vs. copper area is also graphically depicted in Figure 13. It is important to note the thermal resistance (RJA) and thermal coupling resistance (R) are equivalent for both die. For example at 0.1 square inches of copper: RJA1 = RJA2 = 168oC/W R1 = R2 = 96oC/W TJ1 and TJ2 define the junction temperature of the respective die. Similarly, P1 and P2 define the power dissipated in each die. The steady state junction temperature can be calculated using Equation 4 for die 1 and Equation 5 for die 2. Example: Use Equation 4 to calculate TJ1 and Equation 5 to calculate TJ2 with the following conditions. Die 2 is dissipating 0.5W; die 1 is dissipating 0W; the ambient temperature is 60oC; the package is mounted to a top copper area of 0.1 square inches per die.
5
RHR1K160D
.
T J1 = P 1 R JA + P 2 R + T A
(EQ. 4)
TJ1 = (0W)(168oC/W) + (0.5W)(96oC/W) + 60oC TJ1 = 108oC
T J2 = P 2 R JA + P 1 R + T A (EQ. 5)
copper pad area on single pulse transient thermal impedance. Each trace represents a copper pad area in square inches corresponding to the descending list in the graph. SPICE and SABER thermal models are provided for each of the listed pad areas. Copper pad area has no perceivable effect on transient thermal impedance for pulse widths less than 100ms. For pulse widths less than 100ms the transient thermal impedance is determined by the die and package. Therefore, CTHERM1 through CTHERM6 and RTHERM1 through RTHERM5 remain constant for each of the thermal models. A listing of the model component values is available in Table 1.
TJ2 = (0.5W)(168oC/W) + (0W)(96oC/W) + 60oC TJ2 = 144oC The transient thermal impedance (ZJA) is also effected by varied top copper board area. Figure 14 shows the effect of
200 COPPER BOARD AREA - DESCENDING ORDER 0.020 in2 0.140 in2 0.257 in2 0.380 in2 0.483 in2
IMPEDANCE (oC/W)
ZJA, THERMAL
150
100
50
0 10-1
100
101 t, RECTANGULAR PULSE DURATION (s)
102
103
FIGURE 14. TRANSIENT THERMAL IMPEDANCE vs MOUNTING PAD AREA
6
RHR1K160D SPICE Thermal Model
REV October 1998 RHR1K160D Copper Area = 0.483 in2 CTHERM1 th 8 6e-6 CTHERM2 8 7 4e-5 CTHERM3 7 6 1.5e-4 CTHERM4 6 5 7.5e-4 CTHERM5 5 4 7e-3 CTHERM6 4 3 2e-2 CTHERM7 3 2 8e-2 CTHERM8 2 tl 2.5 RTHERM1 th 8 5e-2 RTHERM2 8 7 2.5e-1 RTHERM3 7 6 1.5 RTHERM4 6 5 2.5 RTHERM5 5 4 7.5 RTHERM6 4 3 22 RTHERM7 3 2 38 RTHERM8 2 tl 38
th JUNCTION
RTHERM1 8
CTHERM1
RTHERM2 7
CTHERM2
RTHERM3 6
CTHERM3
RTHERM4 5
CTHERM4
SABER Thermal Model
Copper Area = 0.483 in2 template thermal_model th tl thermal_c th, tl { ctherm.ctherm1 th 8 = 6e-6 ctherm.ctherm2 8 7 = 4e-5 ctherm.ctherm3 7 6 = 1.5e-4 ctherm.ctherm4 6 5 = 7.5e-4 ctherm.ctherm5 5 4 = 7e-3 ctherm.ctherm6 4 3 = 2e-2 ctherm.ctherm7 3 2 = 8e-2 ctherm.ctherm8 2 tl = 2.5 rtherm.rtherm1 th 8 = 5e-2 rtherm.rtherm2 8 7 = 2.5e-1 rtherm.rtherm3 7 6 = 1.5 rtherm.rtherm4 6 5 = 2.5 rtherm.rtherm5 5 4 = 7.5 rtherm.rtherm6 4 3 = 22 rtherm.rtherm7 3 2 = 38 rtherm.rtherm8 2 tl = 38 } TABLE 1. THERMAL MODELS COMPONENT CTHERM7 CTHERM8 RTHERM6 RTHERM7 RTHERM8 0.02 in2 7.5e-2 1 25 65 70 0.14 in2 8e-2 1.5 22 45 55 0.257 in2 8e-2 2 22 40 48
RTHERM5 4
CTHERM5
RTHERM6 3
CTHERM6
RTHERM7 2
CTHERM7
RTHERM8
CTHERM8
tl
AMBIENT
0.38 in2 8e-2 2 22 38 43
0.483 in2 8e-2 2.5 22 38 38
7
RHR1K160D MS-012AA
8 LEAD JEDEC MS-012AA SMALL OUTLINE PLASTIC PACKAGE
E E1 1 e 2 A A1
INCHES SYMBOL A A1 b c MIN 0.0532 0.004 0.013 0.0075 0.189 0.2284 0.1497 MAX 0.0688 0.0098 0.020 0.0098 0.1968 0.244 0.1574
MILLIMETERS MIN 1.35 0.10 0.33 0.19 4.80 5.80 3.80 MAX 1.75 0.25 0.51 0.25 5.00 6.20 4.00 NOTES 2 3 4
D 6
D
b
E E1 e H
5
h x 45o
0.050 BSC 0.0099 0.016 0.0196 0.050
1.27 BSC 0.25 0.40 0.50 1.27
c
L
L 0.060 1.52 0o-8o
0.004 IN 0.10 mm
0.050 1.27 0.024 0.6
0.155 4.0 0.275 7.0 MINIMUM RECOMMENDED FOOTPRINT FOR SURFACE-MOUNTED APPLICATIONS
NOTES: 1. All dimensions are within allowable dimensions of Rev. C of JEDEC MS-012AA outline dated 5-90. 2. Dimension "D" does not include mold flash, protrusions or gate burrs. Mold flash, protrusions or gate burrs shall not exceed 0.006 inches (0.15mm) per side. 3. Dimension "E1" does not include inter-lead flash or protrusions. Inter-lead flash and protrusions shall not exceed 0.010 inches (0.25mm) per side. 4. "L" is the length of terminal for soldering. 5. The chamfer on the body is optional. If it is not present, a visual index feature must be located within the crosshatched area. 6. Controlling dimension: Millimeter. 7. Revision 8 dated 5-99.
1.5mm DIA. HOLE
4.0mm USER DIRECTION OF FEED 2.0mm 1.75mm C L
MS-012AA
12mm TAPE AND REEL
12mm
8.0mm
40mm MIN. ACCESS HOLE 18.4mm COVER TAPE 13mm 330mm 50mm
GENERAL INFORMATION 1. 2500 PIECES PER REEL. 2. ORDER IN MULTIPLES OF FULL REELS ONLY. 3. MEETS EIA-481 REVISION "A" SPECIFICATIONS.
12.4mm
8
RHR1K160D
All Intersil semiconductor products are manufactured, assembled and tested under ISO9000 quality systems certification.
Intersil semiconductor products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see web site www.intersil.com
Sales Office Headquarters
NORTH AMERICA Intersil Corporation P. O. Box 883, Mail Stop 53-204 Melbourne, FL 32902 TEL: (321) 724-7000 FAX: (321) 724-7240 EUROPE Intersil SA Mercure Center 100, Rue de la Fusee 1130 Brussels, Belgium TEL: (32) 2.724.2111 FAX: (32) 2.724.22.05 ASIA Intersil (Taiwan) Ltd. 7F-6, No. 101 Fu Hsing North Road Taipei, Taiwan Republic of China TEL: (886) 2 2716 9310 FAX: (886) 2 2715 3029
9


▲Up To Search▲   

 
Price & Availability of RHR1K160D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X